by Jim Anderson | Jun 21, 2023 | Clamp Hubs
A CouplingCorp customer came with a problem that can be common. The original shaft attachment device they were using had a set screw to hold it in place on the shaft. Over time the vibrations of the hub on the shaft caused micro fretting between the set screw and the...
by Jim Anderson | Jun 21, 2023 | FLEXXOR Couplings, Reciprocating Compressor
For several years a gas gathering company dealt with high vibrations on the motor driving a 6 throw, 5400 HP reciprocating compressor. Over that time, they made several attempts to reduce the levels, but none were successful. On the output end of the motor, the...
by Jim Anderson | Jun 21, 2023 | FLEXXOR Couplings
A large industrial manufacturer came to Coupling Corp with a low torque application designed to run at 75,000 RPM. This was no problem for the FLEXXOR coupling. But to make things harder, they wanted the coupling to mount on their straight cylindrical shafts. Normally...
by Jim Anderson | Jun 21, 2023 | FLEXXOR Couplings
When a wind turbine has a coupling failure, it’s a long way up to get a replacement coupling installed. When a wind turbine has a coupling failure and the coupling OEM is on a different continent, it can mean many weeks of downtime. This is precisely what...
by Jim Anderson | Jun 21, 2023 | Quill Shaft, York* Compressor Replacement Coupling
It can with York* Replacement Couplings from CCA Every year as the temperature rises and chiller systems are beginning to run, CouplingCorp gets calls from customers whose York* compressors have an unexpected problem. This past year a customer had an original York...